← Back to Knowledge Base
Affect Performance Team
|Analytics|Nov 25, 2026

How Google Tag Gateway Enables First-Party Google Tracking in JENTIS

In October 2026, JENTIS introduced several updates to its server-side tracking platform. The company added Health Center to monitor tag execution, expanded the settings for the jts-rw first-party cookie in Essential Mode, and announced support for Google Tag Gateway.

The updates were published on October 1 and 14. They address three components of marketing data infrastructure: diagnosing tag execution errors, routing Google tracking requests, and managing user identifiers before consent is obtained.

Health Center: Monitoring Server-Side Tag Performance

On October 1, JENTIS introduced Health Center, a system for monitoring tag health in server-side containers. Previously, when errors occurred, teams might not discover a problem until discrepancies appeared in advertising or analytics reports. For example, if a conversion tag stopped firing, the missing events might become apparent only after data had accumulated.

Health Center monitors tag execution and detects deviations from normal behavior. The system helps identify elevated error rates, missing expected tag fires, and data transmission issues. It displays the operational status of each tag. When a problem is detected, JENTIS displays notifications in the platform interface and can send email alerts.

Monitoring is particularly important after changes to a container's configuration. Errors in triggers, variables, or integration settings can result in lost events even when the underlying infrastructure continues to operate. Health Center helps teams identify the affected tag and begin troubleshooting sooner, without waiting for changes in metrics in GA4 or advertising accounts.

Managing Alert Expiration

On October 14, JENTIS expanded Health Center settings by adding the option to configure alert expiration. This allows teams to control how long notifications remain relevant and reduce the number of outdated messages in the monitoring system. For example, if a team resolves a tag execution problem after a container update, the alert should not continue to be treated indefinitely as a new issue.

Health Center remains a monitoring and diagnostic tool. It does not automatically correct tag configurations or recover events that were not sent while an error was occurring.

Google Tag Gateway: Delivering Google Tags Through a First-Party Route

On October 14, JENTIS announced support for Google Tag Gateway. Google Tag Gateway allows Google tags to load and measurement requests to be routed through infrastructure associated with the advertiser's own domain, rather than having the browser connect directly to Google's standard domains. This approach provides first-party routing for measurement requests.

In a traditional configuration, the Google tag loads from Google's infrastructure and sends measurement data to the relevant services. With Google Tag Gateway, part of this interaction takes place through a configured route on the website's side. Support for Google Tag Gateway in JENTIS expands the options for building data collection infrastructure for companies that use both server-side tag management and Google tools.

However, first-party routing does not automatically eliminate all browser restrictions or user consent requirements. Accurate measurement still depends on tag configuration, consent handling, and the availability of measurement requests. The October JENTIS changelog entry did not provide details on pricing conditions or the step-by-step setup process for the new integration.

In its October updates, JENTIS also expanded the settings for the jts-rw first-party cookie. JENTIS uses jts-rw as a visitor identifier. It helps link events processed through the JENTIS infrastructure.

JENTIS documentation describes scenarios in which the platform's own cookies may be created before the user makes a final consent decision. One involves Essential Mode, a data processing mode with a separate configuration for permitted operations. The update allows users to use a short-lived identifier with a configurable lifetime.

This matters for companies where the data protection team or Data Protection Officer (DPO) imposes additional requirements on how long identifiers can be stored before consent is obtained. For example, a company can limit the identifier's lifetime in Essential Mode rather than use the standard cookie retention period.

Cookie lifetime and the lawfulness of data processing are separate issues. Shortening the retention period does not replace an assessment of the legal basis for processing or automatically authorize data transmission to advertising platforms.

How Essential Mode Works

Essential Mode allows teams to configure specific data processing scenarios when a user has not yet consented to nonessential tracking. In JENTIS, tag execution rules are configured separately according to vendor settings and the applicable consent mode. For example, a company can configure the collection of certain technical signals before the visitor makes a decision, while restricting data transmission to external systems.

The availability of Essential Mode does not mean that all advertising or analytics tags can run without consent. Each scenario requires a determination of which operations are permitted, which data can be used, and under what conditions the data can be transmitted.

Another change announced on October 14 concerns Cookie Lifetime Extender, a JENTIS tool for managing the resilience of first-party cookies to browser restrictions. Cookie Lifetime Extender is designed to extend the lifetime of identifiers in the presence of browser tracking prevention mechanisms, including Safari Intelligent Tracking Prevention restrictions. It requires an appropriate configuration of the server infrastructure or CDN that processes requests.

In its October update, JENTIS improved Cookie Lifetime Extender validation messages. The system provides more detailed diagnostic information when it detects configuration issues. This helps technical specialists identify which settings need to be corrected sooner.

The update addresses diagnostics rather than changing the cookie lifetime extension mechanism itself. Cookie Lifetime Extender capabilities and support for different CDNs were already available in JENTIS.

JENTIS: A Server-Side Tracking and Marketing Data Management Platform

JENTIS is a platform for server-side collection and processing of marketing data. It allows teams to manage tags, collect signals from websites, process events, and send them to analytics and advertising systems.

Unlike fully browser-based tracking, a server-side architecture moves part of the data processing into controlled infrastructure. This provides additional options for managing transmitted parameters, consent rules, and integrations. The platform includes tools for server-side tag management, consent configuration, user identifier management, and monitoring data transmission quality.

The October updates develop JENTIS's existing capabilities in several areas. Health Center helps detect tag execution errors. Google Tag Gateway support adds a first-party routing option for Google tracking. The jts-rw settings expand the options for managing identifier retention in Essential Mode. Together, these changes strengthen control over marketing measurement infrastructure, from individual tag execution to event routing and user consent handling.

Sources

Monthly Overview

Stay ahead of the market. Every month.

Our practitioners pick the TOP 10–20 news from the world of Paid Media and MarTech for the month.

10–20Top news / month